Quote in 15 min·24/7 × 365AS9120:2025 · ISO 9001:2015 · FAA AC 00-56B
NSN 5925-01-317-9964CAGE F0555
0219494G00
Circuit Breaker
Circuit Breaker ASAP can help source this line with documentation review, alternate part checks, condition requirements, and account manager follow-up for urgent or planned procurement.
Mbda France
Manufacturer
USA
Origin
N/A
Spec
N/A
Unit weight
Detailed description
Technical sourcing notes
N/A
Lead time
N/A
Cross references
Unrestricted
Export control
5925 Circuit Breakers
FSC
Why ASAP
Operations-grade aviation sourcing.
AS9120B
Quality-managed distribution
15 min
Average RFQ response, 24/7
Full trace
Documentation & certs on request
Submit RFQ
Request a quote for 0219494G00
Send this part to ASAP with quantity, need-by timing, and buyer contact details. An account manager will review availability, alternates, certificates, and delivery options.
Part-specific RFQ
Submit RFQ for 0219494G00
Send this part to ASAP with quantity, need-by timing, and buyer contact details. A dedicated account manager reviews availability, alternates, certificates, and delivery options.
Circuit Breaker0219494G00
NSN5925-01-317-9964
- Manufacturer
- Mbda France
- CAGE
- F0555
Characteristics Data of NSN 5925-01-317-9964, 5925013179964
| MRC | Criteria | Characteristic |
|---|---|---|
| AAJE | THREAD PITCH DIAMETERS | +0.4752/+0.4787 INCHES |
| AAQL | ||
| ABXD | BUSHING LENGTH | 0.625 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 2.000 INCHES NOMINAL |
| ADAT | BODY WIDTH | 1.500 INCHES NOMINAL |
| ADTV | CASE MATERIAL | PLASTIC |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.530 INCHES NOMINAL |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.750 INCHES NOMINAL |
| AEFN | NONTURN DEVICE LOCATION | AT 3 OCLOCK AND AT 9 OCLOCK |
| AEFQ | NONTURN DEVICE LENGTH | 0.130 INCHES NOMINAL |
| AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.200 INCHES MAXIMUM |
| AKPX | POLE QUANTITY | 2 |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.0 AMPERES AC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3500.0 AC ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 ALL LOCATIONS |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| CQJX | NOMINAL THREAD SIZE | 0.500 INCHES |
| CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED AND SHOCK RESISTANT AND VIBRATION RESISTANT |
| CRTK | SWITCH TERMINAL TYPE | QUICK DISCONNECT, MALE |
| CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 10.0 AC AND 5.0 DC |
| FREQ | FREQUENCY IN HERTZ | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
| PKWT | UNPACKAGED UNIT WEIGHT | 6.000 OUNCES |
| THSD | THREAD SERIES DESIGNATOR | UN |
| TTQY | TERMINAL TYPE AND QUANTITY | 4 QUICK DISCONNECT, MALE |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC ALL LOCATIONS |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 50.000 MINIMUM AT 125 PCT ALL LOCATIONS AND 700.000 MAXIMUM AT 125 PCT ALL LOCATIONS AND 30.000 MINIMUM AT 150 PCT ALL LOCATIONS AND 400.000 MAXIMUM AT 150 PCT ALL LOCATIONS AND 10.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 150.000 MAXIMUM AT |
| AEFP | NONTURN DEVICE RADIUS | 0.656 INCHES NOMINAL |
| AEFS | NONTURN DEVICE DIAMETER | 0.151 INCHES MINIMUM AND 0.161 INCHES MAXIMUM |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
| CPRQ | RESET METHOD | MANUAL |
| CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
| CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC AND 30.0 DC |